Language selection icon ATAGO CO.,LTD. THE BrixMeister ys
ATAGO SHOP Support
Pipeline Fitting
Pipeline Fitting

In-line Refractometer

Pipeline Fitting

Sample Inlet List

Lineup

Straight type

Ferrule (with blanking plate)

Straight typeFerrule (with blanking plate)

Straight type

Flange (with blanking plate)

Straight typeFlange (with blanking plate)

Straight type

Screw (with blanking plate)

Straight typeScrew (with blanking plate)

L type

Ferrule

L typeFerrule

L type

Flange

L typeFlange

L type

Screw

L typeScrew

Bypass

Hose Connector 12mmΦ

Hose Connector 12mmΦ

Bypass

Triple Hose Connector 12mmΦ

Triple Hose Connector 12mmΦ

Bypass

Compression Fitting 10mmΦ

Compression Fitting 10mmΦ

Fitting Sizes List

JIS G3447 / IDF(ferrule / screw)
Size Outer diameter Inner diameter
1.0S 25.4 23.0
1.25S 31.8 29.4
1.5S 38.1 35.7
2.0S 50.8 47.8
2.5S 63.5 59.5
3.0S 76.3 72.3
3.5S 89.1 85.1
4.0S 101.6 97.6
4.5S 114.3 108.3
JIS G3459(flange)
Size Outer diameter Inner diameter
20A 27.2 23.0
25A 34.0 28.4
32A 42.7 37.1
40A 48.6 43.0
50A 60.5 54.9
65A 76.3 70.3
80A 89.1 83.1
90A 101.6 95.6
100A 114.3 108.3

(Unit of length:mm)

Correct Installation Methods

Sample Inlet
● Please install the detector section below or to the side of the sample inlet.
Due to gravity, the liquid settles at the bottom while air occupies the upper portion. Therefore, If the detecotor section is installed at the top, the liquid may not come into contant with the prism surface, which is used to measure the concentration. Additionally, when installing the detector section on the side of the sample inlet, the liquid may not reach the prism surface if the flow rate is too low and the liquid level drops. Please ensure that a sufficient sample flow rate is maintained at all times.
Correct example Incorrect example
● Please ensure that the sample flows upward, from the bottom to the top, inside the sample inlet.
If the sample flows from top to bottom inside the sample inlet, air bubbles will gradually accumulate at the upper part of the inlet, potentially causing measurement errors.
Correct example Incorrect example
RecommendationsWe recommend installing valves up stream and downstream of the sample inlet.
For maintenance or inspecting the condition of the prism, valves are required to temporarlly stop the sample flow when removing the detector section from the sample inlet.
Detection Section

Straight ferrule with blanking plate Example : CM-800α

Straight ferrule with blanking plate

Hose Connector Example : CM-BASEα

Hose Connector Hose Connector

Tank installation  Example : PRM-TANKα(FER)

Tank installation  Example : PRM-TANKα(FER)

・Clamp

・Clamp

※ ※Sample flow direction ※Sample flow direction

Tank installation Example : PRM-TANKα(FER)

Tank installation

Product Details

[ RE-67511  1S Straight Ferrule with blanking plate ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67511
  • RE-67511
  • RE-67511
  • RE-67511
  • RE-67511

[ RE-67512  1.5S Straight Ferrule with blanking plate ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67512
  • RE-67512
  • RE-67512
  • RE-67512
  • RE-67512

[ RE-67521  2S Straight Ferrule with blanking plate ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67521
  • RE-67521
  • RE-67521
  • RE-67521
  • RE-67521

[ RE-67522  2.5S Straight Ferrule with blanking plate ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67522
  • RE-67522
  • RE-67522
  • RE-67522
  • RE-67522

[ RE-67531  3S Straight Ferrule with blanking plate ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67531
  • RE-67531
  • RE-67531
  • RE-67531
  • RE-67531

[ RE-67537  4S Straight Ferrule with blanking plate ]

〇 Simplified Dimensions

簡易寸法図 図面依頼中

〇 Connection Example (PRM-100α)

接続例 図面依頼中
RE-67537
  • RE-67537
  • RE-67537
  • RE-67537
  • RE-67537

[ RE-67568  10A Straight Flange with blanking plate ]

〇 Simplified Dimensions

簡易寸法図 図面依頼中

〇 Connection Example (PRM-100α)

接続例 図面依頼中
RE-67568
  • RE-67568
  • RE-67568
  • RE-67568

[ RE-67570  25A Straight Flange with blanking plate ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67570
  • RE-67570
  • RE-67570
  • RE-67570
  • RE-67570

[ RE-67574  40A Straight Flange with blanking plate ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67574
  • RE-67574
  • RE-67574
  • RE-67574
  • RE-67574

[ RE-67576  50A Straight Flange with blanking plate ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67576
  • RE-67576
  • RE-67576
  • RE-67576
  • RE-67576

[ RE-67526  65A Straight Flange with blanking plate ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67526
  • RE-67526
  • RE-67526
  • RE-67526
  • RE-67526

[ RE-67583  80A Straight Flange with blanking plate ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67583
  • RE-67583
  • RE-67583
  • RE-67583
  • RE-67583

[ RE-67578  100A Straight Flange with blanking plate ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67578
  • RE-67578
  • RE-67578
  • RE-67578
  • RE-67578

[ RE-67513  1S Straight Screw with blanking plate ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67513
  • RE-67513
  • RE-67513
  • RE-67513
  • RE-67513

[ RE-67523  2S Straight Screw with blanking plate ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67523
  • RE-67523
  • RE-67523
  • RE-67523
  • RE-67523

[ RE-67533  3S Straight Screw with blanking plate ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67533
  • RE-67533
  • RE-67533
  • RE-67533
  • RE-67533

[ RE-67538  4S Straight Screw with blanking plate ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67538
  • RE-67538
  • RE-67538
  • RE-67538
  • RE-67538

[ RE-67611  1S L type Ferrule ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67611
  • RE-67611
  • RE-67611
  • RE-67611
  • RE-67611

[ RE-67616  1.5S L type Ferrule ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67616
  • RE-67616
  • RE-67616
  • RE-67616
  • RE-67616

[ RE-67621  2S L type Ferrule ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67621
  • RE-67621
  • RE-67621
  • RE-67621
  • RE-67621

[ RE-67626  2.5S L type Ferrule ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67626
  • RE-67626
  • RE-67626
  • RE-67626
  • RE-67626

[ RE-67631  3S L type Ferrule ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67631
  • RE-67631
  • RE-67631
  • RE-67631
  • RE-67631

[ RE-67671  25A L type Flange ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67671
  • RE-67671
  • RE-67671
  • RE-67671
  • RE-67671

[ RE-67673  40A L type Flange ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67673
  • RE-67673
  • RE-67673
  • RE-67673
  • RE-67673

[ RE-67675  65A L type Flange ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67675
  • RE-67675
  • RE-67675
  • RE-67675
  • RE-67675

[ RE-67678  100A L type Flange ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67678
  • RE-67678
  • RE-67678
  • RE-67678
  • RE-67678

[ RE-67613  1S L type Screw ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67613
  • RE-67613
  • RE-67613
  • RE-67613
  • RE-67613

[ RE-67623  2S L type Screw ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67623
  • RE-67623
  • RE-67623
  • RE-67623
  • RE-67623

[ RE-67633  3S L type Screw ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67633
  • RE-67633
  • RE-67633
  • RE-67633
  • RE-67633

[ RE-67501  Bypass Hose Connector 12mmΦ with buffing ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67501
  • RE-67501
  • RE-67501
  • RE-67501
  • RE-67501

[ RE-67502  Bypass Hose Connector 12mmΦ without buffing ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67502

[ RE-67641  Bypass Hose Connector 12mmΦ Prism Wiper with buffing ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67508

[ RE-67591  Bypass Hose Connector 12mmΦ Prism Wiper without buffing ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67591
  • RE-67591
  • RE-67591
  • RE-67591
  • RE-67591

[ RE-67505  Bypass Triple Hose Connector 12mmΦ with buffing ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67505
  • RE-67505
  • RE-67505
  • RE-67505
  • RE-67505

[ RE-67506  Bypass Triple Hose Connector 12mmΦ without buffing ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67506
  • RE-67506
  • RE-67506
  • RE-67506
  • RE-67506

[ RE-67503  Bypass Compression Fitting 10mmΦ with buffing ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67503
  • RE-67503
  • RE-67503
  • RE-67503
  • RE-67503

[ RE-67504  Bypass Compression Fitting 10mmΦ without buffing ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67504
  • RE-67504
  • RE-67504
  • RE-67504
  • RE-67504

[ RE-67509  Bypass Compression Fitting 10mmΦ Prism Wiper with buffing ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67509
  • RE-67509
  • RE-67509
  • RE-67509
  • RE-67509

[ RE-67644  Bypass Compression Fitting 10mmΦ Prism Wiper without buffing ]

〇 Simplified Dimensions

Simplified Dimensions

〇 Connection Example (PRM-100α)

Connection Example
RE-67592